Home About Us Dealer Network Products Contact Us Enquiry
 
Meters Data Logger Temperature Controller Street Light Controller Current Transformer Electronic Timer Voltage Monitor Relay
Engine Starting Relay Toggler Relay Fault
Annunciation Unit
Water Level Controller & Indicator Hooter & Buzzer Submersible
Pump Starter
Busbar Supports & Insulator

ASIAN ELECTRICAL GROUP - ISO 9001:2015

- Price List , Catalogue

VOLTAGE MONITOR RELAY
Solid state electronic device for automation and protection against voltage. Wide under/over voltage setting range are available for both 1 and 3 phase systems. Trip time is adjustable from 1 to 10 seconds. Adjustable drop off/pick up differential Common, Setting for all phases.

UNDER VOLTAGE RELAY, 1 PHASE, AU-200
VOLTAGE SETTING : 160V TO 262V
TIME SETTING : 1 to 10 SEC

OVER VOLTAGE RELAY, 1 PHASE, AO-200
VOLTAGE SETTING : 220V TO 330V
TIME SETTING : 1 to 10 SEC

UNDER+OVER VOLTAGE RELAY, 1 PHASE, AUO-200
UNDER VOLTAGE RELAY, 3 PHASE, AU-400
VOLTAGE SETTING : 300V TO 400V
TIME SETTING : 1 to 10 SEC

OVER VOLTAGE RELAY, 3 PHASE, AO-400
VOLTAGE SETTING : 400V TO 500V
TIME SETTING : 1 to 10 SEC

UNDER+OVER VOLTAGE RELAY, 3 PHASE, AUO-400
VOLTAGE SETTING : 300V-400V UNDER, 420V-500V, OVER
TIME : 4 SEC, FIXED

SINGLE PHASE PREVENTOR RELAY, ASP-2
VOLTAGE SETTING : 160V-220 UNDER
230V-300V OVER

TIME 4 SEC FIXED
Solid state electronic device to protect 3-phase motors or any other equipment against single phasing unbalanced supplied
and reverse phasing. Both auto manual reset models are available.

REVERSE POWER RELAY, ARP-105
OVER OR UNDER CURRENT RELAY/ EARTH FAULT RELAY

Solid state electronic device for automation and protection and protection against over current (over load) current setting is continuously adjustable from 1 to 5 amps. AC (for higher values, use suitable CT), Built-in-delay timer to avoid spurious tripping, adjustable from 1 to 10 seconds and operates on AC or DC voltage

UNDER OR OVER VOLTAGE + OVER CURRENT RELAY AU OC -210
OVER CURRENT RELAY, AOC-107

EARTH FAULT RELAY, AEF- 106

COMBINED 1 EARTH FAULT-2 OVER CURRENT, A30C-111
3 OVER CURRENT RELAY, A30C-111

FREQUENCY MONITOR RELAY, AMF-115
Solid state electronic device for automation and protection and protection against frequency. Frequency is
continuously settable from 45 to 55 Hz for under or over frequency operations. Auto or manual reset, avoid spurious tripping in-built with adjustable range of 1-0 sec

EARTH LEAKAGE RELAY, AEL-108
Solid state electronic device for protection of electrical machines and equipment against insulation, break down and earth
leakage. Current setting : 30-300 ma or 50-500 ma or 100-100 mam (adjustable). Tripping time : 50msec operation voltage any
AC or DC

Phase sequence corrector relay, APSC- 1000

Heater & Pump relay, AHP-125

Fuse failure relay, AFF-135

 


Copyright 2013 Asian Electrical Group. All Rights Reserved.